| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Change in completion method from fully cemented liner to wet shoe configuration allowing frac out, with 150' setback at toe and over-displacement by 7 barrels creating 400' uncemented annulus. ๐ Sundry Form for Well File No. 41473, Additional Sundry Data; Mud and Cementing Plan; Proposed Wellbore Schematic Non-standard completion design enabling wireline perforating without tubing or tractor, reducing costs and complexity in tight spacing. |
2025-11-17 | Completions / Frac |
| Tier 3 |
Lateral drilled in 38.48 hours on bottom with average ROP of 350.2 ft/hr, facies breakdown 2.5% B, 65.4% C, 32.1% D, and formation dip averaging 89.83ยฐ. ๐ Well Information; Days vs. Depth Graph High-efficiency drilling performance in Middle Bakken, with specific facies targeting indicating optimized geosteering. |
2026-01-19 | Directional Drilling |
| Tier 3 |
Waiver for drill cutting samples in vertical section below curve kickoff, with 30' intervals resuming in curve and 200' in lateral. ๐ Sundry Form for Well File No. 41473 - Drill Cutting Samples Waiver Deviation from standard sampling frequency, leveraging offset well data for efficiency in multi-well pad. |
2025-11-04 | Regulatory / Permitting |
| Tier 3 |
Suspension of drilling for up to 90 days to use smaller rig for surface hole, with plug placement to prevent contamination.โฐ TIME-SENSITIVE ๐ Sundry Form for Well File No. 41473 - Suspension of Drilling Unusual phased drilling approach to optimize rig utilization and reduce upfront costs in pad development. |
2025-10-29 | Drilling Rigs |
| Tier 3 |
Waiver for open hole logs, relying on offset well CRYING TREE 8-1H within 1 mile, with GR-CBL planned from TD to surface. ๐ Sundry Form for Well File No. 41473 - Open Hole Log Waiver Non-routine logging strategy to minimize costs by referencing nearby well data. |
2025-07-31 | Regulatory / Permitting |
| Tier 3 |
Mud program specifies invert diesel in vertical hole (0'-11,653' MD) and brine in horizontal (11,653'-21,896' MD), with closed-loop system and no pit. ๐ Mud and Cementing Plan Custom mud system tailored to hole sections, avoiding traditional pits for environmental compliance. |
Relative | Mud / Fluids |
| Tier 3 |
No diesel-based compounds in hydraulic stimulation fluids, with commitment to reduce flaring via sales pipeline tie-in. ๐ Mud and Cementing Plan; Gas Capture Plan Environmental compliance measures beyond standard, prioritizing clean stimulation and gas capture. |
Relative | General Oilfield Services |