| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Use of 'wet shoe' liner configuration with intentional over-displacement to create uncemented annulus, enabling wireline perforating without tubing. ๐ Full Well Details - Wet Shoe Discussion Unconventional liner design choice to facilitate completion operations. |
Relative | Completions / Frac |
| Tier 3 |
Waiver granted for open hole logs, citing reference well Hartsoch 33-33 within a mile, with GR-CBL planned from TD to ground level. ๐ Sundry Notice for Waiver Request Non-standard regulatory approval to bypass open hole logging, potentially reducing costs and timeline. |
2025-05-15 | Regulatory / Permitting |
| Tier 3 |
ETJ notification to City of Tioga for pad within extraterritorial jurisdiction, including BMPs like fencing, alarms, and containment. ๐ City of Tioga ETJ Notification Letter Enhanced safety and environmental commitments for urban-adjacent operations. |
2025-03-31 | General Oilfield Services |
| Tier 3 |
Notification to adjacent operator Murex Petroleum for drill-back through adjacent spacing unit, including wellbore diagram and contact info. ๐ Affidavit Affirming Drill-Back Notification Proactive compliance with NDIC Order 31848 for horizontal wells entering adjacent units. |
2025-03-26 | General Oilfield Services |