| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Variance approved for tubing/packer requirement with assurances on casing integrity, pressure monitoring, and fluid properties. ๐ Sundry Form for Tubing/Packer Waiver Allows completion without packer, relying on casing design, uncommon in high-pressure Bakken completions. |
2025-09-24 | General Oilfield Services |
| Tier 3 |
100% of lateral drilled in Middle Bakken zone, with overall dip 90.5ยฐ. ๐ Geological Summary Perfect zone adherence in challenging horizontal drilling, indicating high-quality execution. |
2025-12-10 | General Oilfield Services |
| Tier 3 |
Use of Starsteer software for wellbore steering, targeting 10' window within Middle Bakken C/D contact. ๐ Geological Summary - Horizontal Wellbore Precise geosteering software integration for facies targeting, beyond standard MWD. |
2025-12-08 | General Oilfield Services |
| Tier 3 |
Specific bit and motor selection: Reed RH54-A3 6" drill bit and Baker mud motor with 1.4ยฐ bend for lateral drilling. ๐ Geological Summary - Horizontal Wellbore Non-standard tool combination for optimized lateral performance in Bakken. |
2025-12-08 | Mud / Fluids |
| Tier 3 |
Formation tops deviated from prognosis: Base of Last Salt 4' deeper, Mission Canyon 7' deeper. ๐ Geological Summary Unexpected subsurface variations requiring real-time adjustments. |
2025-12-05 | General Oilfield Services |
| Tier 3 |
Operator obtained waiver for drill cutting samples in vertical portion, collecting 30' intervals from offsetting well Charlene Ferrari 9-4 1H-LL on same pad instead of this well. ๐ Sundry Form for Drill Cutting Samples Waiver Reduces sampling costs and operational overhead by leveraging adjacent well data, uncommon practice requiring regulatory approval. |
2025-09-30 | Regulatory / Permitting |
| Tier 3 |
Waiver granted for filter sock container requirement, as operator does not use filter media during drilling. ๐ Sundry Form for Filter Sock Container Waiver Exempts from standard waste management protocols, indicating specialized mud system or filtration avoidance. |
2025-09-23 | Mud / Fluids |
| Tier 3 |
Waiver for open hole logs, using GR-CBL from offsetting well Charlene Ferrari 9-4 4H within 1 mile. ๐ Sundry Form for Open Hole Log Waiver Avoids redundant logging, leveraging nearby well data for formation evaluation. |
2025-06-10 | Regulatory / Permitting |