| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Operator requested and received suspension of drilling (SOD) for up to 90 days to use smaller rig for surface hole only, then return with larger rig to TD.โฐ TIME-SENSITIVE ๐ Suspension of Drilling Sundry (FORM ID: 262822) Non-standard drilling sequence to achieve cost savings. Requires coordination between two different rig contractors and creates a 90-day window for larger rig mobilization. |
2025-08-08 | Drilling Rigs |
| Tier 2 |
Multiple regulatory waivers approved: tubing/packer requirement, filter sock container for drilling phase, and open hole logs. ๐ Various Sundry Forms (262828, 262819, 262811) Operator successfully obtained multiple regulatory concessions, indicating established relationship with NDIC and confidence in alternative compliance methods. |
2025-08-07 to 2025-08-11 | Regulatory / Permitting |
| Tier 2 |
Design includes 'wet shoe with ability to frac out the toe' and backup hyd toe sleeve in case wet shoe fails, plus ball seat for testing liner. ๐ Proposed Work and Section Details Unusual completion design with redundant systems for toe initiation. Wet shoe approach differs from standard plug-and-perf. |
Unknown | Completions / Frac |
| Tier 3 |
Pad located within Watford City's Extra-Territorial Jurisdiction AND on an aquifer, triggering extensive site-specific stipulations including closed mud system, impermeable liner, H2S plan, fencing, perimeter berm, and special casing requirements. ๐ Permit stipulations pages 2-3 Dual regulatory triggers (municipal jurisdiction + aquifer) create complex compliance requirements that exceed standard Bakken well specs. |
2026-01-14 | Mud / Fluids |
| Tier 3 |
Operator proactively conducted geotech and depth-to-groundwater analysis for pad expansion over aquifer and communicated with Watford City planner prior to permit submission. ๐ Wehrung Pad BMP Letter (July 22-23, 2025) Shows proactive regulatory engagement and pre-permit stakeholder management. Operator invested in site characterization before formal application. |
2025-07-23 | General Oilfield Services |
| Tier 3 |
Verbal approval granted for MWD failure contingency - allowed to drill blind from survey at 21348' MD an additional 347' with specific risk warning to stop a joint of pipe before the limit. ๐ INSPECTOR COMMENTS section Regulatory exception for equipment failure shows operational flexibility and risk tolerance. Inspector explicitly states operator proceeds at own risk, indicating potential geosteering or survey challenges. |
Unknown | General Oilfield Services |
| Tier 3 |
Operator requested flexibility to add Dakota string 'if/when needed' citing elevated Dakota pressure experienced on adjacent SKAAR pad. ๐ PROPOSED WORK section Contingency planning based on offset well experience shows anticipation of potential pressure problems. Design allows for mid-operation modification. |
Unknown | General Oilfield Services |