| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Use of a 'wet shoe' sub in the production liner to intentionally over-displace cement by 2 bbls and allow first stage frac out the shoe. ๐ Completion Equipment section and Drilling Prognosis Non-standard cementing/completion technique designed for specific zonal isolation and frac initiation, indicating engineered completion design. |
Unknown | Completions / Frac |
| Tier 3 |
Well name change request from EN-Van Berkom-157-93-2627H-3 to EN-Van Berkom-157-93-2627H-3U approved via sundry. ๐ Sundry Form, Description (Operator) and Additional Sundry Data sections Indicates a post-permit modification, possibly for unitization, re-entry, or regulatory alignment, creating a distinct well identity for tracking and operations. |
2026-05-05 | General Oilfield Services |
| Tier 3 |
Anticollision report generated June 5, 2025, shows close approaches (Separation Factor <1.5) with multiple offset wells on the same pad.โฐ TIME-SENSITIVE ๐ Anticollision Report summary and ladder plot Recent engineering analysis confirming tight spacing with pad siblings (H-2, H-4, H-5) and an existing well (2627H-1), elevating drilling risk. |
2025-06-05 | Directional Drilling |
| Tier 3 |
Detailed, engineered pad and access road design by KLJ Engineering with extensive erosion control and interim reclamation specifications. ๐ Well/Facilities Pad & Access Road Design sheets, Plan Notes Extensive, prescriptive civil design exceeding typical permit notes, indicating high environmental compliance focus and pre-construction planning maturity. |
2025-05-19 | General Oilfield Services |
| Tier 3 |
Affidavit from Hess Senior Manager confirming Halliburton Energy Services does not use specified diesel fuels in HF operations, dated April 21, 2022. ๐ Letter from Tom Richardson, Senior Manager - Drilling & Completions A dated, signed affidavit addressing specific regulatory (EPA) compliance for hydraulic fracturing fluids, pre-emptively locking in a major service provider. |
2022-04-21 | Completions / Frac |
| Tier 3 |
Explicit anti-collision statement details Hess's internal standards (1.5 separation factor, MWD survey frequency, geo-steering with Gamma ray). ๐ Proposed Work - Anti-Collision Statement section Reveals operator's proprietary collision avoidance protocols beyond NDIC minimums, indicating a dense drilling environment and operational rigor. |
Unknown | Directional Drilling |
| Tier 3 |
Specific NDIC Field Inspector contact (Dylan Roach at 701-770-1981) mandated for pre-construction notification. ๐ Conditions of Approval section Unusual to name a specific inspector in the permit; indicates heightened regulatory oversight or site-specific concerns requiring direct coordination. |
Unknown | General Oilfield Services |