| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Operator requested and received approval for suspension of drilling for up to 90 days to use a smaller rig for surface hole only, then move off and bring larger rig within 90 days to complete drilling.โฐ TIME-SENSITIVE ๐ WELL SUNDRY FORM - Sundry Type: Request for Consideration/Waiver Reveals a staged, cost-saving drilling strategy that creates two distinct rig mobilization/demobilization events and a 90-day window for larger rig services. |
2025-11-19 | Drilling Rigs |
| Tier 2 |
Operator declared use of a 'wet shoe' liner configuration (400' uncemented annulus at toe) to enable pump-down wireline perforating for first stage, avoiding more expensive tubing/tractor methods. ๐ Full Well Details section - Discussion of 'Standard Wet Shoe' Explicit design choice to reduce completion cost for stage 1, indicating preference for wireline services over tubing-conveyed or tractor methods. |
Unknown | Completions / Frac |
| Tier 3 |
Motor failure at 25,580' MD in lateral required TOOH and ~21.5 hour downtime before resuming drilling. ๐ Sample Descriptions - notation at 15 | Page Downhole motor failure in lateral indicates equipment stress, potentially leading to additional motor runs, fishing operations, or BHA redesign. |
2025-12-25 | General Oilfield Services |
| Tier 3 |
Drilling plan includes a trip out of hole (TOOH) at 10,892' MD due to build rate issues during curve, with resumed building after a ~17.5 hour delay. ๐ Geological Summary - Curve section Unplanned operational disruption indicates directional drilling challenges, potentially requiring BHA changes or additional directional supervision. |
2025-12-20 | Directional Drilling |
| Tier 3 |
NDIC reviewer imposed condition: 'surface holes are not to be intentionally deviated' due to potential severe casing wear during vertical/curve drilling. ๐ WELL SUNDRY FORM - REVIEWER COMMENTS Regulatory restriction on surface hole deviation indicates awareness of casing wear risks, potentially influencing BHA design and directional drilling approach. |
2025-11-19 | Directional Drilling |
| Tier 3 |
NDIC required specific sample collection protocol: 30' intervals in vertical/build, 200' in lateral, with shipment to state core library within 30 days of drilling completion.โฐ TIME-SENSITIVE ๐ Letter from Ross Edison, Geologist, ND Geological Survey Regulatory mandate with strict timeline for sample handling and shipment, not standard for all wells. |
2025-09-29 | General Oilfield Services |