| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Use of 'wet shoe' liner configuration (400' uncemented annulus at toe) to enable wireline pump-down perforating for first stage, avoiding tubing/tractor. ๐ Full Well Details section, 'WET SHOE' description Non-standard cementing/completion design choice to reduce cost and complexity for toe initiation; indicates preference for wireline over coiled tubing/tractor for Stage 1. |
Unknown | Completions / Frac |
| Tier 3 |
Core and sample collection mandate with strict deadlines: cuttings within 30 days of drilling completion, cores within 180 days.โฐ TIME-SENSITIVE ๐ RE: CORES AND SAMPLES letter Regulatory directive with civil penalty risk ($12,500 per offense); imposes post-drilling logistics burden for sample handling and shipping. |
2025-09-29 | General Oilfield Services |
| Tier 3 |
Drill-back notification to adjacent operator (Devon Energy) for wellbores exiting target spacing unit, indicating potential interference management and coordination requirements.โฐ TIME-SENSITIVE ๐ AFFIDAVIT AFFIRMING DRILL-BACK NOTIFICATION Proactive regulatory compliance for multi-well pad with lateral exits; reveals operator coordination with competitor (Devon) and potential for operational sequencing conflicts. |
2025-09-03 | Completions / Frac |
| Tier 3 |
Explicit anti-collision protocol with 1.2 separation safety factor in intermediate sections, real-time corrected surveys, and gamma ray signatures for existing wellbore identification. ๐ ANTI-COLLISION STATEMENT Detailed, operator-specific collision avoidance measures exceed basic regulatory requirements; indicates high-density drilling area with proximity to multiple existing wells. |
Unknown | Directional Drilling |
| Tier 3 |
Waiver requested for open hole logs (no open hole logs planned), relying on cement bond log and wellsite geologist discretion with prior approval. ๐ EVALUATION PROGRAM section Operator opting out of standard porosity/resistivity logging suite, reducing evaluation costs but increasing reliance on geologist and regulatory approval for changes. |
Unknown | Regulatory / Permitting |
| Tier 3 |
Regulatory requirement to contact NDIC Field Inspector Jessica Gilkey prior to location construction, with specific phone number provided.โฐ TIME-SENSITIVE ๐ Conditions of Approval - Construction Commencement Notification Named inspector with direct contact requirement indicates heightened regulatory oversight for pad construction; non-compliance could delay spud. |
Relative | General Oilfield Services |
| Tier 3 |
Specific cementing design for production casing includes 50:50 Class G cement with D035 Poz Extender and expanding agent (D053) for salt sections. ๐ CEMENTING PROGRAM section Custom cement blend tailored for salt zones (Charles, Pine Salt) indicates geotechnical challenges; use of expanding agent suggests focus on annular isolation in reactive formations. |
Unknown | General Oilfield Services |