| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
North setback condition based on a production liner cemented in the lateral with a wet shoe and ability to frac out the shoe, a specific engineering design constraint. ๐ Page 1 of 10, Conditions of Approval section Regulatory approval is contingent on a specific completion design (cemented liner with wet shoe). This is a non-standard condition that dictates the completion method and limits options. |
Unknown | Completions / Frac |
| Tier 3 |
Permit modification to relocate surface hole location from 600' FNL 2553' FWL to 400' FNL 2538' FWL in Section 22, indicating pad layout optimization or surface constraint resolution. ๐ Page 7 of 10, PROPOSED WORK section Shows active pad redesign after initial permit, suggesting ongoing engineering adjustments, potential surface access issues, or multi-well pad optimization. Competitors should note the shift in surface footprint. |
2026-07-13 | General Oilfield Services |
| Tier 3 |
Waiver granted for open hole logs based on offset well AMBER 2234-7BH (File #41761) within a mile, relying on its logs and a GR-CBL from TD to ground level. ๐ SUNDRY FORM FOR WELL FILE NO.: 42353, DESCRIPTION (OPERATOR) section Operator is avoiding open hole logging costs by leveraging nearby well data. This indicates a cost-saving strategy and reliance on offset data quality. It also implies the offset well's logs are deemed sufficient, reducing evaluation services for this well. |
2026-06-09 | Regulatory / Permitting |
| Tier 3 |
Explicit anti-collision report submitted and referenced, with specific separation factors and warnings (e.g., Level 3 with Amber 2203-3BH).โฐ TIME-SENSITIVE ๐ KLX Anticollision Report sections, e.g., '1.875 Level 3, SF' with Amber 2234-7BH Shows high-density drilling environment with close wellbore proximity. Level 3 warnings indicate elevated risk requiring careful navigation. The report is dated May 2026, showing recent planning. |
2026-05-04 | Directional Drilling |
| Tier 3 |
Closed mud system with no cuttings pit specified, and all drill cuttings will be disposed at 13 Mile Landfill, Williston, ND. ๐ Page 1 of 10 (STIPULATIONS) and Drilling Fluids Program section Mandates a specific waste handling method (closed loop, offsite landfill) rather than onsite pits. This is an environmental and operational constraint that affects waste management logistics. |
Unknown | Mud / Fluids |
| Tier 3 |
Requirement to drill in conjunction with a well that meets a 1220' setback from east and west spacing unit boundaries to justify the spacing unit. ๐ Page 2 of 10 This well's approval is tied to the drilling of another specific well (likely on the same pad) that satisfies stricter setback rules. Creates interdependency and sequencing pressure. |
Unknown | General Oilfield Services |