| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 | Wet shoe configuration: Intentional over-displacement by 7 barrels to create uncemented annulus for toe initiation, allowing pump-down of perforating guns on wireline. Details of Standard Wet Shoe Esther Federal 4697 42-33 4B discussion. |
Unknown | Completions / Frac |
| Tier 3 | Email notification of potential federal permit requirement for spacing unit involving BLM coordination.⏱ URGENT Email from Emma Neigum dated December 18, 2025. |
2025-12-18 | General Oilfield Services |
| Tier 3 | Waiver requested for notification to adjacent operator under Order No. 31848, as operator is the same for the spacing unit. Letter dated November 12, 2025, from Ryan Emery to NDIC. |
2025-11-12 | Regulatory / Permitting |
| Tier 3 | Anti-collision precautions include real-time corrected surveys, 1.2 separation safety factor, gamma ray signatures for wellbore identification, and surveys every 93-100 feet increasing as needed. Anti-Collision Statement. |
Unknown | Directional Drilling |
| Tier 3 | Permit includes conditions for 150' north/south and 1220' east/west setbacks within the 2560-acre spacing unit, with production liner cemented in lateral and ability to frac out the shoe. Permit Stipulations under NDIC Field Order Info. |
Unknown | Completions / Frac |
| Tier 3 | Pre-selected licensed disposal facilities for dry cuttings: Chimney Butte Environmental LLC, Petrocomp, Dishon Disposal Inc., Prairie Disposal LLC, Ideal Oilfield Disposal LLC, IHD Solids Management LLC, Tervita Corporation, Secure Energy Services. Licensed Facilities for Solid Drill Cuttings Disposal list. |
Unknown | General Oilfield Services |
| Tier 3 | Operator will not use any diesel-based compounds in hydraulic stimulation fluids, citing specific CAS registry numbers. Diesel Based Stimulation Fluids/Compounds statement. |
Unknown | General Oilfield Services |