| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Approval granted under Commission Order No. 34326 with specific setback conditions for 1920-acre spacing unit. ๐ Page 1, Stipulations Non-standard setback requirements (500' north/south, 150' east/west) tied to production liner with wet shoe for frac-out capability, indicating regulatory customization for horizontal drilling in Bakken. |
Unknown | Completions / Frac |
| Tier 2 |
Use of wet shoe on production liner with ability to frac out the toe, including backup hydraulic toe sleeve. ๐ Page under Proposed Work and Tubular Details Non-standard completion design for toe initiation, with redundancy, indicating intent for efficient lateral access without coiled tubing. |
Unknown | Completions / Frac |
| Tier 3 |
Permit approved with submission date 02/09/2026 and approval date 02/12/2026.โฐ TIME-SENSITIVE ๐ Page 10, Submitted and Approved By Rapid approval cycle (3 days), enabling operations start after additional 3 business days post-publication. |
2026-02-12 | General Oilfield Services |
| Tier 3 |
Operator assertion of waiver for backbuild order notification due to self-operating adjacent spacing units under NDIC Orders 31848 & 31973. ๐ Backbuild Order Waiver Letter Waives standard inter-operator notices, indicating Phoenix's integrated asset control and reduced external coordination needs. |
2026-02-09 | Regulatory / Permitting |
| Tier 3 |
Drill cuttings disposal to specific licensed facility: Smoky Butte Environmental LLC at 13310 94th Street NW, Fortuna, ND. ๐ Page under Disposal of Drill Cuttings Pre-selected disposal vendor in closed-loop system, avoiding pits, and complying with environmental regs. |
Unknown | Mud / Fluids |
| Tier 3 |
Notification to NDIC upon spudding, including drilling contractor and rig details, within 3 business days via Sundry Notice. ๐ Page 2, Stipulations Requires immediate post-spud reporting with contractor specifics, exposing operational sequencing and potential rig assignments. |
Relative | Drilling Rigs |
| Tier 3 |
Requirement for closed mud system, remote shutoff devices, and pre-construction contact with NDIC Field Inspector Robert Stafford.โฐ TIME-SENSITIVE ๐ Page 2, Stipulations Mandates environmental and safety protocols beyond routine permits, including specific inspector contact, signaling heightened regulatory scrutiny in Divide County. |
Unknown | Mud / Fluids |
| Tier 3 |
Commitment to no diesel-based compounds in hydraulic stimulation, listing specific CAS numbers. ๐ Page under Stimulation Explicit ban on diesel additives, aligning with NDIC environmental policies, and requiring alternative frac fluids. |
Unknown | Completions / Frac |