| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Wet shoe configuration on production liner, intentionally over-displaced by 7 barrels to create uncemented annulus for toe initiation. ๐ Discussion section in permit application Non-standard liner design allowing wireline pump-down of first-stage perforating guns, avoiding more expensive tubing or tractor methods. |
Unknown | Completions / Frac |
| Tier 3 |
Surface Use Agreement executed with landowner for drilling into off-lease units from pad location. ๐ Affidavit Affirming Surface Use Agreement dated February 26, 2026 Legal arrangement enabling horizontal reach into adjacent units, with landowner awareness. |
2026-02-26 | General Oilfield Services |
| Tier 3 |
Waiver requested for notification to adjacent operator under Order No. 31973, as Oasis operates both the subject and adjacent spacing units. ๐ Letter dated January 6, 2026, and Affidavit dated February 26, 2026 Demonstrates operator's control over multiple units, enabling horizontal drilling from outside the target spacing unit without external notifications. |
2026-01-06 | Regulatory / Permitting |
| Tier 3 |
Exemption for indirect heater setback under NDIC Case No. 28949 Order No. 31500, allowing placement within 60 feet of wellhead and 21 feet of oil tank. ๐ Facility Statement Regulatory variance for facility design, prioritizing compact pad layout over standard setbacks. |
Unknown | General Oilfield Services |
| Tier 3 |
Anti-collision measures include real-time corrected surveys, 1.2 separation safety factor, gamma ray signatures for wellbore identification, and surveys every 93-100 feet increasing as needed. ๐ Anti-Collision Statement Enhanced safety protocols beyond basic requirements, using advanced surveying and logging for collision avoidance. |
Unknown | Directional Drilling |
| Tier 3 |
Pre-selected licensed facilities for solid drill cuttings disposal: Chimney Butte Environmental LLC, Dishon Disposal Inc, Ideal Oilfield Disposal LLC, IHD Solids Management LLC, Petrocomp, Prairie Disposal LLC, Secure Energy Services, Tervita Corporation. ๐ Licensed Facilities for Solid Drill Cuttings Disposal section Vendor ecosystem locked in for waste management, with closest facility to be used. |
Unknown | General Oilfield Services |
| Tier 3 |
Commitment to no diesel-based stimulation fluids, excluding CAS numbers 68334-30-5, 68476-34-6, 68476-30-2, 68476-31-3, and 8008-20-6. ๐ Diesel Based Stimulation Fluids/Compounds section Explicit avoidance of diesel compounds in fracturing, aligning with environmental regulations and operator preferences. |
Unknown | Completions / Frac |