| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Wet shoe configuration on 4-1/2" liner with intentional over-displacement of cement by 7 barrels, creating ~400' uncemented annulus for economic toe initiation via pump-down perforating guns. ๐ Attachment 6 in Section 10, Wet Shoe discussion and Fig. 1.1 Non-standard liner cementing to enable cost-saving perforating method, deviating from typical full cement isolation. |
Unknown | Completions / Frac |
| Tier 3 |
Waiver requested for notification to adjacent operator under Order No. 31848, as Oasis is the operator of the adjacent spacing unit. ๐ Letter dated February 19th, 2026, RE: Rosencrans wells Self-waiver due to operator control over adjacent unit, simplifying regulatory process in multi-well pad scenario. |
2026-02-19 | Regulatory / Permitting |
| Tier 3 |
Anticipated drilling commencement on June 7, 2025, with completion approximately 30 days thereafter.โฐ TIME-SENSITIVE ๐ Anticipated Starting Dates in Attachment 6 Specific timeline for operations in a future-dated permit, providing early visibility into activity window. |
2025-06-07 | Drilling Rigs |
| Tier 3 |
Closed mud system with no cuttings pit, and cuttings disposal to licensed facilities including Chimney Butte Environmental LLC, Dishon Disposal Inc., etc. ๐ New Pad Construction Statement and Licensed Facilities list in Attachment 6 Mandated environmental compliance choice in a new pad, specifying disposal vendors and closed-loop mud handling. |
Unknown | Mud / Fluids |
| Tier 3 |
Anti-collision measures include AC guidance reporting, real-time corrected surveys, 1.2 separation safety factor, gamma ray signatures for wellbore identification, and surveys every 93'-100' in lateral. ๐ Anti-Collision Statement in Attachment 6 Detailed, proactive anti-collision protocol beyond standard NDIC requirements, indicating high-risk awareness in dense pad development. |
Unknown | Directional Drilling |