| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Permit approval conditional on a 500' north/south and 150' east/west setback within a 2560-acre spacing unit, with east setback based on a cemented production liner with a wet shoe and ability to frac out the shoe. ๐ Stipulations section, Page 2 of 10 Specific, non-standard setback condition tied to a precise completion design (cemented liner with wet shoe). Deviations require regulatory re-approval. |
2026-05-08 | Completions / Frac |
| Tier 3 |
Mandatory core and sample submission to ND Geological Survey with strict deadlines (30 days for cuttings, 180 days for cores) and high penalty risk ($12,500 per day violation).โฐ TIME-SENSITIVE ๐ Letter from Ross Edison, Geologist, dated 5/12/2026 Regulatory requirement with severe financial penalties for non-compliance; creates a post-drilling logistics and documentation deadline. |
2026-05-12 | General Oilfield Services |
| Tier 3 |
Operator asserts use of real-time corrected surveys, anti-collision standards with 1.5 separation factor, and active geo-steering with Gamma ray to avoid existing wellbores. ๐ Proposed Work / Anti-Collision Statement, Page 7 of 10 Reveals a formal, documented anti-collision protocol exceeding basic requirements, indicating a dense drilling environment and operational risk mitigation. |
2026-05-08 | Directional Drilling |
| Tier 3 |
Affidavit confirms notification and plan sharing with Devon Energy Williston, LLC (adjacent unit operator) via FedEx and email on February 3, 2026, for off-spacing entry. ๐ Drilling Permit Affidavit by Derek Abrahamsen Demonstrates proactive, documented regulatory compliance and inter-operator communication for a complex, multi-unit well path. |
2026-02-03 | General Oilfield Services |
| Tier 3 |
Detailed, engineered pad design by KLJ Engineering includes specific quantities for excavation, embankment, surfacing, and interim reclamation, with a proposed disturbance of 14.19 acres. ๐ Engineered Well Pad design sheets (multiple pages) Extensive, pre-designed civil construction plan with quantified materials. Shows high level of pre-investment and planning for a multi-well pad. |
2026-01-28 | General Oilfield Services |
| Tier 3 |
Operator must contact NDIC Field Inspector Dylan Roach (701-770-1981) prior to location construction. ๐ Stipulations section, Page 2 of 10 Personalized, named inspector contact is a pre-construction gate. Indicates heightened regulatory oversight or site-specific sensitivities. |
Relative | General Oilfield Services |