โ† Back to Daily Permits

๐Ÿ›ข๏ธ LINDVIG 23-22-21-20F 5H

DEVON ENERGY WILLISTON, L.L.C ยท McKenzie County, ND ยท File #42925 ยท Generated 2026-08-22 01:46

API
3305310805
Target Formation
Middle Bakken
Confidence
High

๐Ÿ“Š Signals (5)

Tier Signal Date Service Impact
Tier 2 West setback exception granted based on production liner cemented in lateral with wet shoe and ability to frac out the shoe
๐Ÿ“„ Stipulations section, first page
Non-standard setback approval tied to specific completion design (wet shoe with frac-out capability)
Unknown Completions / Frac
Tier 3 Operator must notify BLM Dickinson office (701-227-7713) due to federal minerals in spacing unitโฐ TIME-SENSITIVE
๐Ÿ“„ Email from Nathaniel Erbele dated 5/11/2026
Additional federal regulatory layer identified after permit approval; requires separate BLM coordination
2026-05-11 General Oilfield Services
Tier 3 Operator filed sworn affidavit notifying Oasis Petroleum (Chord Energy) of adjacent unit penetration per NDIC Order 31848
๐Ÿ“„ Sworn affidavit dated 3/24/2026
Formal regulatory compliance step completed with competitor notification; demonstrates proactive regulatory management
2026-03-24 General Oilfield Services
Tier 3 Waiver requested for multiple proposed logs (Acoustic/Sonic, Cased Hole, Casing Evaluation, Cement Evaluation, Density/Porosity, Drilling/Mud)
๐Ÿ“„ Geologic Information section, Page 4
Multiple log waivers requested suggests operator may rely on alternative data sources or has confidence in existing subsurface knowledge
Unknown Mud / Fluids
Tier 3 Permit includes explicit requirement to contact NDIC Field Inspector Marc Binns (701-220-5989) prior to location construction
๐Ÿ“„ Stipulations section, first page
Specific inspector named with direct contact requirement creates a regulatory checkpoint that must be cleared before any construction begins
Unknown General Oilfield Services

๐Ÿ’ก Operator Intent

๐Ÿ”ง Service Operator Relevance

Pad Construction & Earthwork
Permit approved 5/11/2026 with requirement to contact inspector Marc Binns before construction; detailed earthwork quantities (57,050 CY excavation) and specifications provided
Cementing & Liner Services
Non-standard cement design with wet shoe system required for setback exception; specialized cement blends specified for intermediate casing
Waste Management
Closed mud system with cuttings disposal at Secure Energy Services; filter sock container requirement from spud through flowback
Federal Regulatory Coordination
BLM notification required due to federal minerals; service operators may need to demonstrate BLM compliance awareness