| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Wet shoe configuration detailed: 400 ft uncemented annulus at liner toe, over-displaced by 7 bbls to enable wireline pump-down of first stage guns. ๐ Wet Shoe section, Wellbore Schematics Specific, non-standard cementing/completion design to enable cost-effective toe initiation, directly linked to permit condition. |
Unknown | Completions / Frac |
| Tier 2 |
Approval conditional on 150' north/south and 500' east/west setbacks within 2560-acre spacing unit, with south setback based on production liner cemented in lateral with wet shoe and ability to frac out the shoe. ๐ Stipulations section, Page 1 Specific, non-standard setback conditions tied to a unique wellbore construction (wet shoe) and completion technique, indicating regulatory negotiation and tailored design. |
Unknown | Completions / Frac |
| Tier 3 |
Drill-back notification affidavit certifying email to Devon Energy on 2/11/2026 regarding wellbores entering Bakken outside target spacing unit. ๐ Affidavit Affirming Drill-Back Notification Formal, notarized compliance with drill-back policy, revealing interaction with specific competitor (Devon) and advanced regulatory diligence. |
2026-02-11 | General Oilfield Services |
| Tier 3 |
Anticipated commencement date: Jul 15, 2025.โฐ TIME-SENSITIVE ๐ Anticipated Starting Dates, Section 1.8 Explicit start date provided in planning documents, indicating firm operational timeline. |
2025-07-15 | General Oilfield Services |
| Tier 3 |
CBL required on 9-5/8" intermediate (Dakota water string) prior to setting 7" casing, plus standard CBL on 7" casing. ๐ Page 2 Extra cement bond log requirement on intermediate string beyond standard practice, indicating heightened regulatory scrutiny on aquifer protection. |
Unknown | General Oilfield Services |
| Tier 3 |
Operator must contact NDIC Field Inspector Jessica Gilkey prior to location construction.โฐ TIME-SENSITIVE ๐ Construction Commencement Notification, Page 1 Explicit, named inspector pre-approval requirement for pad construction, not just spudding. |
Relative | General Oilfield Services |
| Tier 3 |
Waiver requested for proposed logs (Acoustic, Cased Hole, etc.) via separate sundry notice. ๐ Geologic Information / Proposed Logs, Page 3-4 Operator intends to forego standard open-hole logging suite, requiring regulatory approval. |
Unknown | Regulatory / Permitting |
| Tier 3 |
Perimeter berm required, closed mud system with no cuttings pit, remote/automatic shutoff devices required on all equipment. ๐ Permit Review Policy, Page 1 Bundled, stringent environmental and safety controls mandated as permit conditions. |
Unknown | Mud / Fluids |