| Tier | Signal | Date | Service Impact |
|---|---|---|---|
| Tier 2 |
Approval conditional on 150' north/south and 500' east/west setbacks within 2560-acre spacing unit, with south setback based on production liner cemented in lateral with wet shoe and ability to frac out the shoe. ๐ Stipulations section, page 1 Specific geomechanical condition tied to completion design (wet shoe) for regulatory approval, indicating a tailored engineering solution to meet spacing requirements. |
Unknown | Completions / Frac |
| Tier 2 |
Wet shoe configuration detailed: 400 ft of uncemented annulus at liner toe, over-displaced by 7 bbls to enable wireline pump-down perforating for toe initiation. ๐ Section 1.11 Wet Shoe and schematic Non-standard liner cementing design to facilitate cost-effective toe initiation, revealing a specific completion methodology choice. |
Unknown | Completions / Frac |
| Tier 3 |
Drill-back notification provided to adjacent operator (Devon Energy) via email on February 11, 2026, as required for off-spacing unit drilling. ๐ AFFIDAVIT AFFIRMING DRILL-BACK NOTIFICATION Demonstrates regulatory compliance and inter-operator coordination for a wellbore traversing adjacent units, mitigating conflict risk. |
2026-02-11 | General Oilfield Services |
| Tier 3 |
Affidavit affirming surface use agreement with landowner for off-lease drilling, executed February 10, 2026. ๐ AFFIDAVIT AFFIRMING SURFACE USE AGREEMENT Legal document confirms surface access secured for pad location outside target spacing unit, a prerequisite for drilling. |
2026-02-10 | General Oilfield Services |
| Tier 3 |
Anticipated commencement date: Jul 15, 2025. Drilling days: Approximately 30.โฐ TIME-SENSITIVE ๐ Section 1.8 Anticipated Starting Dates Firm start date and duration provided in planning documents, indicating advanced scheduling and resource commitment. |
2025-07-15 | Drilling Rigs |
| Tier 3 |
CBL required on 9-5/8" intermediate casing prior to setting 7" casing, plus standard CBL on 7" casing. ๐ Page 2 Extra cement bond log requirement beyond routine, indicating regulatory or operational concern about zonal isolation in intermediate string. |
Relative | General Oilfield Services |
| Tier 3 |
Operator must contact NDIC Field Inspector Jessica Gilkey prior to location construction.โฐ TIME-SENSITIVE ๐ Conditions of Approval, page 1 Explicit, named regulatory point of contact required before pad construction begins, indicating heightened oversight or specific site sensitivities. |
Relative | General Oilfield Services |
| Tier 3 |
Operator asserts it will not use diesel-based compounds in hydraulic stimulation fluids and provides list of prohibited CAS numbers. ๐ Section 1.9 DIESEL BASED STIMULATION FLUIDS/COMPOUNDS Explicit prohibition of diesel in frac fluids, reflecting environmental policy or regulatory compliance strategy that influences chemical sourcing. |
Unknown | Completions / Frac |